CASE STUDY #06 • COMMERCIAL TENANT IMPROVEMENT Plantation, FL

Plantation Commercial Retail Plaza Tenant Improvement

Fast-track 6,500 sq ft commercial retail and professional office tenant improvement in Midtown Plantation, executing structural steel framing modifications, MEP rough-ins, ADA compliance, and impact storefront glazing 12 days ahead of contractual lease opening.

Request Similar Scope Estimate Speak with John: (754) 301-6747
Project Telemetry Data VERIFIED COMPLIANCE
Client Entity Midtown Plantation Commerce Center
Municipal Authority City of Plantation Building Department
Permit Reference Permit #COM-2024-05183
Mandate Standard Florida Building Code Commercial • ADA Title III
Scope Scale 6,500 SQ FT Interior • 4 Commercial Bays
Contract Value – Turnkey Interior Build
Supervising Qualifier: John Kraja • CGC1517295 • CCC1329271

The Commercial Challenge: Strict 90-Day Lease Window & Structural Walls

A national tenant signing a 10-year commercial lease faced strict financial penalties if the retail space was not opened within a fixed 90-day construction delivery window.

The existing shell space required major structural reconfiguration, including removing two central load-bearing masonry walls to create an open customer showroom. In addition, existing plumbing lines were improperly pitched for commercial ADA restrooms, requiring slab saw-cutting and utility trenching.

Because the space sat beneath a commercial roof, installing heavy rooftop HVAC units required certified roof curb penetrations without voiding the plaza landlord's existing commercial roof warranty. Single-trade general contractors lacked in-house roofing authority, leading to project stalls.

6,500
Square Feet Built Out
12 Days
Ahead of Schedule
1st Pass
Fire & Health TCO Pass
100%
Roof Warranty Preserved
Plantation commercial retail plaza tenant improvement and storefront glazing
Verified On-Site Construction • Plantation, FL

The Engineering Execution: Dual-License Fast-Track Management

Leveraging dual Florida licenses (CGC1517295 & CCC1329271), Planet Construction coordinated structural alterations and rooftop penetrations under unified qualifier oversight.

01

Expedited Permitting & Private Provider Plan Review

Coordinated engineering drawings through private provider plan review under Florida Statute 553.791, cutting municipal permit issuance turnaround by 18 business days.

Florida Statute 553.791 Expedited Permitting
02

Structural Steel Moment Frame Erection

Erected structural W-shape steel beams and columns to replace load-bearing CMU walls, transferring gravity loads safely into engineered footing pads under AWS certified welding.

AISC Steel Standards • AWS D1.1 Certified Welding
03

Concrete Slab Saw-Cutting & MEP Trenching

Precision wet saw-cutting of the 5-inch concrete floor slab to trench gravity waste lines for ADA commercial restrooms, followed by re-pour with 4,000 PSI non-shrink concrete.

ADA Standards for Accessible Design
04

Rooftop RTU Curb Penetration & Certified Flashing

Installed new 10-ton commercial rooftop HVAC units, flashing curbs directly into existing TPO roof under roofing license CCC1329271 with full landlord warranty preservation.

NRCA Certified Roof Curb Detail
05

Commercial Architectural Finishes & TCO Sign-Off

Installed Level 5 drywall, custom architectural lighting, impact commercial storefront entrance doors, and passed fire marshal life-safety inspections on the very first walk.

Zero-Punch Standard • Certificate of Occupancy

Technical Specifications & Municipal Verification Log

Every material and method deployed adhered strictly to Florida Building Code, manufacturer warranties, and signed engineering calculations.

Scope Parameter Engineered Specification Governing Standard Verification Method
Structural Reinforcement W12x26 Wide-Flange Structural Steel Beam with engineered steel columns AISC 360 / Florida Building Code Special Inspector Weld & Bolt Torque Log
Electrical Infrastructure New 400A 120/208V 3-Phase commercial service panel with copper feeders NEC 70 Commercial Standard City Rough & Final Electrical Pass
Mechanical / HVAC Two 10-Ton high-efficiency commercial RTU units with economizers FBC Energy Conservation Code TAB Certified Air Balance Report
ADA Compliance Complete Title III ADA compliant restrooms with grab bars & clearances ADAAG Title III Standards Municipal Building Final Inspection
Life-Safety Systems NFPA 13 quick-response fire sprinkler drops and illuminated egress signage NFPA 101 Life Safety Code City Fire Marshal Hydrostatic Test Sign-Off
“Planet Construction completed our commercial build-out 12 days ahead of schedule, enabling us to open for business ahead of our contractual lease deadline. Their ability to handle both interior structural steel and commercial roof penetrations without subcontract delays was invaluable.”
★
Sarah L. • Managing Director Midtown Plantation Commerce Center • Verified 5.0 Google Review

Offering Entire Superior Services Solutions

Single-source general contracting, coastal roofing, and structural restoration engineered for South Florida.

Genti Kraja (John) - Planet Construction Qualifying Contractor

Request Project Estimate for Your Property

Contact our engineering and estimating department to review architectural plans, schedule an on-site structural takeoff, or coordinate municipal permit filings directly with qualifying contractor John Kraja.

Direct Qualifier Contact

Central Office: (754) 301-6747
Official Office Email: office@planetconstructionservices.com
Direct Dispatch: 1500 NE 51st St, Fort Lauderdale, FL 33334

Direct Scope Inquiry Form

Direct submission to our project estimating and engineering department.