Boca Raton Operational Sector Structural Trade Silo #1

Boca Raton Concrete Restoration & Structural Balcony Repair

Certified structural concrete remediation for condominiums, HOAs, and commercial facilities across Boca Raton. From post-tension slab repairs to ICRI-compliant delamination repairs under Florida SB 4-D milestone mandates. Directly supervised by qualifying contractor John Kraja.

Schedule Concrete Restoration Assessment Call Dispatch (754) 301-6747
Concrete Structural Engineering Profile Sector Active
Primary Dispatch Hub 1500 NE 51st St, Fort Lauderdale
Local Jurisdiction City of Boca Raton Building Division
Wind Code Standard 170 MPH Wind Speed • Exposure D (Oceanfront & Coastal Intracoastal)
State Contractor Lic. CGC1517295 • CCC1329271 Dual
Mandate Readiness Florida SB 4-D / SB 154 Milestone Ready
Execution Model 100% Direct In-House Crews

ICRI Technical Standards for Concrete Remediation in Boca Raton

Treating structural concrete deterioration like simple cosmetic plaster patching guarantees premature re-spalling. Planet Construction enforces forensic substrate excavation, steel de-rusting, galvanic sacrificial anodes, and high-performance polymer mortars engineered for long-term structural integrity.

Milestone Phase 2 Permit Guarantee

All shoring calculations, structural hydro-demolition, and post-tension strand re-stressing are executed strictly to signed/sealed engineer-of-record specifications and City of Boca Raton Building Division codes.

01

Acoustic Sounding & Delamination Mapping

Chain-drag acoustic testing and ultrasonic measurements identify hollow delaminations beneath the slab surface before concrete fractures openly onto walkways or common areas.

ASTM C597 • ICRI Technical Guideline 210.3
02

Precision Hydro-Demolition & Steel Undercutting

Damaged concrete is chipped back past the corroded rebar circumference with a minimum 3/4-inch clearance to allow 360-degree encapsulation of new structural mortar.

ICRI Guideline No. 310.1R Edge Preparation
03

Rebar Blast Cleaning & Zinc Sacrificial Anodes

Rebar is needle-scaled to bare metal (SSPC-SP 10), coated with zinc-rich rust-inhibiting primers, and fitted with galvanic zinc sacrificial anodes to prevent halo effect corrosion.

NACE SP0290 • ASTM A775 Cathodic Standard
04

Polymer-Modified Structural Repair Mortar

Application of low-shrinkage, fiber-reinforced, silica fume-modified structural mortars matching the exact compressive strength (4,500+ PSI) and modulus of the parent substrate.

ASTM C928 Rapid Hardening Class R3
05

Traffic Bearing Waterproof Membrane & Railing Anchoring

Multi-coat elastomeric PMMA or polyurethane deck coatings seal the cured slab against water penetration, while new railing embeds receive core-drilled non-shrink grout sleeves.

ASTM C957 Multi-Layer System • NOA Approved

Targeted Concrete Restoration Zones in Boca Raton

Local environmental exposures across Boca Raton create distinct engineering challenges requiring localized structural specifications.

Zone 5A: Oceanfront Towers & Condos

A1A Ocean Boulevard & Camino Real Corridor

Ultra-luxury high-rise towers requiring phased milestone restoration, SentryGlas laminated balcony sliders, and PMMA liquid membrane waterproofing.

Zone 5B: Exclusive Country Clubs

Royal Palm Yacht Club & St. Andrews Estates

Architectural standing seam metal and clay tile roof assemblies, large-missile impact curtain walls, and museum-grade finishes built to rigorous estate standards.

Zone 5C: Downtown Financial & Retail

Mizner Park Corridor & Federal Highway Commercial

Class-A commercial interior tenant improvements, storefront impact glazing retrofits, and commercial flat TPO reroofing executed without tenant disruption.

Direct Dual-Licensed Contractor vs. Subcontractor Sales Broker

When your property in Boca Raton requires high-value structural work, direct qualifier leadership ensures code compliance, budget protection, and zero broker markups.

Restoration Parameter Planet Construction (Direct Qualifier) Typical General Contractor Broker
On-Site Supervision ✓ Direct oversight by Qualifying Contractor John Kraja ✕ Commissioned sales rep visits site; zero license qualifier presence
Workforce Model ✓ 100% In-house restoration craftsmen & equipment ✕ Brokered to lowest-bidding third-party sub crews
Licensing Breadth ✓ Dual FL Certified: CGC1517295 + Roofing CCC1329271 ✕ Single-scope license requiring subcontracting of envelope roofing
Change Order Discipline ✓ Pre-mapped sounding logs with photographic verification ✕ Low base bid followed by inflated exploratory change orders
Milestone Certification ✓ Direct sign-off coordination with City of Boca Raton Building Division ✕ Delays caused by disconnect between broker and subs

Offering Entire Superior Services Solutions

Single-source general contracting, coastal roofing, and structural restoration engineered for South Florida.

Genti Kraja (John) - Planet Construction Qualifying Contractor

Request Concrete Restoration Proposal in Boca Raton

Contact our engineering and estimating department to review architectural plans, schedule an on-site structural takeoff, or coordinate municipal permit filings directly with qualifying contractor John Kraja.

Direct Qualifier Contact

Central Office: (754) 301-6747
Official Office Email: office@planetconstructionservices.com
Direct Dispatch: 1500 NE 51st St, Fort Lauderdale, FL 33334

Direct Concrete Restoration Bid Form

Direct submission to our Boca Raton project estimating team.