PEDESTRIAN TRAFFIC
Balconies & Elevated Decks
Multi-layer polyurethane traffic membranes with perimeter cant strips and code-approved drip flashing.
Request Detailed Quote →When water gets into a basement or crawl space, a sump pump is your last line of defense. We install reliable systems with backup power so they work when you need them most.
Sump pump installation in Fort Lauderdale is the active drainage solution for properties where gravity-based drainage systems can't overcome the water table and rainfall volumes that South Florida's climate produces. When a French drain or perimeter drainage system has collected water but there is no suitable gravity discharge point at the right elevation, a sump pump system takes over — actively lifting that water to a discharge point above grade. In Fort Lauderdale's flat, low-lying coastal environment, sump pumps are not a luxury item: for many properties, they are the only reliable solution to keeping below-grade spaces dry.
Cold fluid-applied and PMMA systems cure seamlessly, eliminating lap-joint water entry points.
Diamond grinding and shot-blasting achieve ICRI CSP 3-4 anchor profiles for high-strength chemical bonding.
Single-source responsibility combining General Contractor (CGC1517295) and Roofing Contractor (CCC1329271) licenses.
Sump pumps fail during the storms they were installed to handle — when power goes out, when float switches stick, when the pump can't keep up with the flow, or when there's no battery backup. The result is flooding, damaged finishes, and a recovery process that costs many times what a proper installation would have.
We size pumps based on actual water volumes, install proper basins and check valves, add battery backup systems for power outages, and route discharge lines to the right place. Every install is tested under load, and we explain how to maintain it. The result is a system that works when the storm hits — not just when conditions are perfect.
Sump pump systems are appropriate when groundwater or collected drainage water cannot be discharged by gravity — the most common situation in Fort Lauderdale's flat topography. Properties where the storm drain connections are at a higher elevation than the drainage collection point need a pump to lift water to the discharge level. Below-grade areas — enclosed parking, storage rooms, mechanical spaces — that flood during heavy rain events need a sump system to remove water quickly before it damages equipment and finishes. Retaining walls or foundation perimeters in low-lying areas where gravity drainage to an appropriate discharge point is not possible benefit from sump systems integrated with their perimeter French drain. Properties in Fort Lauderdale's coastal and canal-adjacent areas with water tables that rise to grade level during wet season need active water management that gravity drainage alone cannot provide.
PEDESTRIAN TRAFFIC
Multi-layer polyurethane traffic membranes with perimeter cant strips and code-approved drip flashing.
Request Detailed Quote →
VEHICULAR TRAFFIC
Heavy-duty aggregate-filled elastomeric urethane systems resisting vehicular abrasion and chloride penetration.
View Garage Systems →
SUBTERRANEAN
Hydrostatic pressure barriers, bentonite sheets, and crystalline injection halting water table infiltration.
Inquire About Foundation →
EXPANSION JOINTS
High-movement structural silicone and polyurethane joint sealants for window perimeters and wall transitions.
Explore Joint Sealants →
ROOT-RESISTANT
Root-barrier membranes, drainage boards, and internal flashing terminating soil moisture migration.
Inquire About Planters →
DRAINAGE RELIEF
Commercial cast-iron sump assemblies and perforated gravity drain lines protecting basement and slab levels.
Request Drainage Bid →A complete sump pump installation consists of several integrated components. The sump pit — a lined excavation in the lowest point of the area being protected — collects water from the perimeter drainage system or from direct groundwater infiltration. The submersible sump pump sits within the pit and activates automatically when the water level rises to the trigger point of the float switch. The discharge pipe carries the pumped water to the discharge point — typically above grade at a suitable outfall location away from the building. A check valve prevents pumped water from flowing back into the pit when the pump cycles off. Battery backup systems maintain pump operation during power outages — critical in Fort Lauderdale, where the most intense rainfall events that most demand pump operation are also the most likely to cause power interruptions.
Sump pump backup power is a critical consideration in Fort Lauderdale's hurricane and storm environment. A property that depends on its sump pump to keep below-grade spaces dry during heavy rain events is maximally vulnerable during exactly the conditions that are most likely to knock out grid power — which is why battery backup sump pump systems are standard on Planet Construction FL's sump pump installations wherever power outages are a realistic concern. Battery backup systems provide full pump operation for several hours on a fully charged battery, covering most Fort Lauderdale storm events. For properties where longer backup duration is needed — hurricane season properties in flood-prone areas — generator-powered backup or dual-pump systems with independent power sources provide greater resilience.
Acoustic hammer sounding for hidden delaminations, diamond grinding to CSP 3-4, and concrete crack routing.
Chipping spalls, treating corroded steel, forming perimeter cove seal fillets, and detail-flashing all drains.
Two-component epoxy moisture barrier primer penetrating concrete pores to eliminate outgassing and maximize pull-off strength.
High-build elastomeric membrane basecoat, reinforced fiber scrim, and aggregate-broadcast UV topcoat for non-slip protection.
A sump pump system that fails during a storm event produces the worst possible outcome — flooding in a space that was designed to be protected. Planet Construction FL recommends annual maintenance for all sump pump installations: testing the pump by manually triggering the float switch to confirm proper operation; inspecting the discharge pipe for blockage, freeze damage (rare in Fort Lauderdale), or root intrusion; testing the check valve to confirm it is seating properly; and replacing the battery in battery backup systems every 3–5 years regardless of apparent condition. For properties in high-risk flood areas, twice-annual inspection before hurricane season and before wet season is a worthwhile investment in system reliability when it matters most.
Phased construction logistics, resident notices, reserve study alignment, and direct engineer of record milestone recertification sign-offs.
Engineering-compliant high-performance traffic membranes, structural joint sealants, and building envelope moisture defenses across Broward and Palm Beach counties.
Multi-layer polyurethane pedestrian traffic membrane, cove perimeter detailing, and non-slip wear course over 48 residential units.
Shot-blast surface profiling, heavy vehicular urethane membrane application, and reflective stall restriping over 4 levels.
Post-tension cable pocket sealing, railing post embedment waterproofing, and fluid PMMA elastomeric deck coating.
Direct answers on membrane longevity, inspection protocols, resident coordination, and warranty coverage across South Florida.
Sump pump capacity — measured in gallons per hour (GPH) at the required discharge head height — is sized based on the expected water inflow rate to the sump pit, which depends on the drainage area being protected, the soil's water transmission rate, and the worst-case rainfall intensity the system must handle. Planet Construction FL sizes sump pump capacity for each installation based on these site-specific factors — undersized pumps allow water levels to rise faster than they can discharge, leading to flooding despite having a sump system in place.
Yes — sump pumps should be connected to a dedicated GFCI-protected electrical circuit sized for the pump's amperage draw. Sharing a circuit with other loads risks tripping the breaker during pump operation. The GFCI requirement protects against electric shock in the inherently wet sump pit environment. Electrical work for sump pump installation is performed by a licensed electrician subcontractor working with our installation team.
A properly sized sump pump system handles normal South Florida rain events effectively. For major storm events — tropical storms, hurricanes — the volume of water entering the system may exceed the pump's capacity during the peak inflow period. Battery backup systems and adequate pit volume to buffer peak inflow help bridge these peak periods. For properties in designated flood zones, additional flood mitigation measures beyond sump pumping may be appropriate in coordination with your flood insurance requirements.
Quality submersible sump pumps in residential applications typically last 7–12 years with normal operation and annual maintenance. In Fort Lauderdale's wet climate where pumps cycle more frequently than in drier regions, service life may be at the lower end of this range. We specify commercial-grade pumps for applications with high cycling frequency, which provide longer service life and greater reliability in demanding operating conditions.
Request a comprehensive moisture diagnostic, membrane pull-off test, or turnkey board proposal. We provide detailed line-item bids backed by dual state contractor licenses.